Model No. - RSD-100C-5
Max Output Wattage (W) - 100 Watts
Output Voltage (VDC) - 5 Volts
Model No. | RSD-100B-5 | RSD-100B-12 | RSD-100B-24 | RSD-100C-5 | RSD-100C-12 | RSD-100C-24 | RSD-100D-5 | RSD-100D-12 | RSD-100D-24 | |
Output: | DC Voltage | 5V | 12V | 24V | 5V | 12V | 24V | 5V | 12V | 24V |
Current Range | 0~20A | 0~8.4A | 0~4.2A | 0~20A | 0~8.4A | 0~4.2A | 0~20A | 0~8.4A | 0~4.2A | |
Rated Current | 20A | 8.4A | 4.2A | 20A | 8.4A | 4.2A | 20A | 8.4A | 4.2A | |
Rated Power | 100W | 100.8W | 100.8W | 100W | 100.8W | 100.8W | 100W | 100.8W | 100.8W | |
Ripple & Noise (max.) | 100mVp-p | 120mVp-p | 150mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | |
Voltage Tolerance | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
Line Regulation | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ±0.3% | ±0.2% | |
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Setup, Rise Time | 800ms, 50ms at full load | |||||||||
Hold up Time | B/C- type complies with S1 level @ full load, comply with S2 level @ 70% load ; D-type complies with S2 level @ full load | |||||||||
Input: | Voltage Range Continuous | 16.8 ~ 31.2 VDC | 33.6 ~ 62.4 VDC | 67.2 ~ 143 VDC | ||||||
Voltage Range 1 sec. | 14.4 ~ 33.6 VDC | 28.8 ~ 67.2 VDC | 57.6 ~ 154 VDC | |||||||
Efficiency (Typ.) | 88% | 89% | 89% | 89% | 91% | 91% | 89.5% | 91% | 90% | |
DC Current (Typ.) | 4.8A / 48V | 4.8A / 48V | 4.8A / 48V | 2.1A / 110V | 2.1A / 110V | 2.1A / 110V | 1.2A / 110V | 1.2A / 110V | 1.2A / 110V | |
Inrush Current (Typ.) | 30A / 24VDC | 30A / 48VDC | 30A / 110VDC | |||||||
Protection: | Overload | 105 ~ 135% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
Over Voltage | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||||
Environment: | Working Temp. | -40 ~ +55°C (no derating) ; +70°C @60% load by free air convection ; +70°C no derating with external base plate, TX class compliance | ||||||||
Working Humidity | 5 ~ 95% RH non-condensing | |||||||||
Storage Temp., Humidity | -40 ~ +85°C, 5 ~ 95% RH | |||||||||
Temp. Coefficient | ±0.03%/°C (0 ~ 50°C) | |||||||||
Vibration | 10 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 | |||||||||
Safety & EMC | Safety Standards | Meet IEC60950-1 (LVD) | ||||||||
Withstand Voltage | I/P - O/P : 4KVAC I/P-FG : 2.5KVDC O/P-FG : 2.5KVDC | |||||||||
Isolation Resistance | I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25°C / 70% RH | |||||||||
EMC Emission | Compliance to EN55022 (CISPR22), Conduction Emission: Class A, Radiation Emission: Class B | |||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8 ; light industry level, criteria A | |||||||||
Railway Standard | Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC | |||||||||
Others: | MTBF | 254.1Khrs min. MIL-HDBK-217F (25°C) | ||||||||
Dimension | 161 x 68 x 36mm (LxWxH) | |||||||||
Packing | 0.6Kg; 24pcs / 15.4Kg / 0.98CUFT |
Electrical Specifications | |
Dimensions | 161 x 68 x 36mm (L x W x H) |
Number of Outputs | 1 |
Output Voltage | 5V |
PDF Specs | View Spec Sheet |
Wattage | 100 |
General | |
Industry Aliases | new |
RSD-100C-5 Mean Well Railway Single Output DC-DC Converter
- Brand: Mean Well
- Product Code: RSD-100C-5
- Availability: Call for Availability
-
$56.70