Mean Well Authorized Distributor since 1997
Model No. - LRS-100 Series
Max Output Wattage (W) - 100 Watts
Output Voltage (VDC) – 3.3, 5, 12, 15, 24, 36, 48 Volts
Model No. |
LRS-150F-24 |
LRS-150F-48 |
|||||
Output: |
DC Voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Rated Current |
22A |
12.5A |
10A |
6.5A |
4.3A |
3.3A |
|
Current Range |
0 ~ 22A |
0 ~ 12.5A |
0 ~ 10A |
0 ~ 6.5A |
0 ~ 4.3A |
0 ~ 3.3A |
|
Rated Power |
110W |
150W |
150W |
156W |
154.8W |
158.4W |
|
Ripple & Noise (max.) Note 2 |
100mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
|
Voltage ADJ. Range |
4.5 ~ 5.5V |
10.2 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 28.8V |
32.4 ~ 39.6V |
43.2 ~ 52.8V |
|
Voltage Tolerance Note 3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
Line Regulation Note 4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load Regulation Note 5 |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Setup, Rise Time |
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
||||||
Hold up Time |
16ms / 230VAC 12ms/115VAC at full load |
||||||
Input: |
Voltage Range |
85~264VAC 120~370VDC |
|||||
Frequency Range |
47~63Hz |
||||||
Efficiency (Typ.) |
85% |
87.5% |
89% |
89% |
89% |
90% |
|
AC Current (Typ.) |
2.8A/115VAC 1.6A/230VAC |
||||||
Inrush Current (Typ.) |
COLD START 60A/230VAC |
||||||
Leakage Current |
<0.75mA / 240VAC |
||||||
Protection: |
Over Load |
110 ~ 140% rated output power |
|||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||
Over Voltage |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
18.75 ~ 21.75V |
28.8 ~ 33.6V |
41.4 ~ 48.6V |
55.2 ~ 64.8V |
|
Protection type: Shut down o/p voltage, re-power on to recover |
|||||||
|
|||||||
Environment: |
Working Temp. |
-30 ~ +70°C (Refer to "Derating Curve") |
|||||
Working Humidity |
20 ~ 90% RH non-condensing |
||||||
Storage Temp., Humidity |
-40 ~ +85°C, 10 ~ 95% RH |
||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
||||||
Vibration |
10 ~ 500Hz, 5G 10min. / 1cycle 60 min. each along X, Y, Z axes |
||||||
Safety & EMC |
Safety Standards |
UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1/-2-16, CCC GB4943 approved |
|||||
Withstand Voltage |
I/P - O/P : 3.75KVAC I/P-FG : 2KVAC O/P-FG : 1.25KVAC |
||||||
Isolation Resistance |
I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25°C / 70% RH |
||||||
EMC Emission |
Compliance to EN5502 (CISPR22) GB9254 Class B, EN55014 EN61000-3-2, -3 |
||||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61000-6-2 (EN50082-2) heavy industry level, criteria A |
||||||
Others: |
MTBF |
648.6Khrs min. MIL-HDBK-217F (25°C) |
|||||
Dimension |
159*97*30mm (L*W*H) |
||||||
Packing |
0.48Kg; 30pcs / 15.4Kg / 0.975UFT |
||||||
|
Electrical Specifications | |
Dimensions | 6.2 x 3.8 x 1.9 in (L*W*H) |
Input Voltage | 85~264VAC |
Number of Outputs | 1 |
Output Voltage | 15V |
PDF Specs | View Spec Sheet |
Wattage | 150 |
General | |
Industry Aliases | new |