Model No. - NPF-60 Series
Max Output Wattage (W) - 60 Watts
Output Voltage (VDC) – 12, 15, 20, 24, 30, 36, 42, 48, 54 Volts
Model No. |
NPF-60-12 |
NPF-60-30 |
NPF-60-42 |
NPF-60-48 | NPF-60-54 | |||||
Output: |
DC Voltage |
12V |
15V |
20V |
24V |
30V |
36V |
42V |
48V | 54V |
Rated Current |
5A |
4A |
3A |
2.5A |
2A |
1.67A |
1.43A |
1.25A | 01.12A | |
Constant Current Range |
7.2 ~ 12A |
9 ~ 15A |
12 ~ 20A |
14.4 ~ 24A |
18 ~ 30A |
21.6 ~ 36A |
25.2 ~ 42A |
28.8 ~ 48V | 32.4 ~ 54V | |
Rated Power |
60W |
60W |
60W |
60W |
60W |
60.12W |
60.06W |
60W | 60.48W | |
Ripple & Noise (max.) Note 2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
200mVp-p | 350mVp-p | |
Voltage Tolerance Note 3 |
±4.0% |
±4.0% |
±4.0% |
±3.0% |
±3.0% |
±2.0% |
±1.0% |
±1.0% | ±1.0% | |
Line Regulation Note 4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% | ±0.5% | |
Load Regulation Note 5 |
±1.5% |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% | ±0.5% | |
Setup, Rise Time |
500ms, 80ms at 95% load 115VAC / 230VAC |
|||||||||
Hold up Time |
16ms / 230VAC 16ms/115VAC at full load |
|||||||||
Input: |
Voltage Range |
90 ~ 305VAC 127~431VDC |
||||||||
Frequency Range |
47~63Hz |
|||||||||
Power Factor (typ.) | PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characterisitc) curve) | |||||||||
Total Harmonic Distortion | THD< 20% when output loading?60% at 115VAC/230VAC input and output loading? 75% at 277VAC input |
|||||||||
Efficiency (Typ.) |
86% |
87% |
88% |
89% |
90% |
90% |
90% |
90% | 90% | |
AC Current (Typ.) |
0.8A/115VAC 0.4A/230VAC 0.32A/277VAC |
|||||||||
Inrush Current (Typ.) |
COLD START 50A(twidth= 270μs measured at 50% lpeak) at 230VAC |
|||||||||
MAX. No. of PSUs on 16A Circuit Breaker | 9 units (circuit breaker of type B)/ 16 units (circuit breaker of type C) at 230VAC | |||||||||
Leakage Current |
<0.25mA / 277VAC |
|||||||||
Protection: |
Over Current |
95 ~ 108% |
||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||||||||
Over Voltage |
15 ~ 17V |
17.5 ~ 21V |
23 ~ 27V |
28 ~ 34V |
34 ~ 40V |
41 ~ 46V |
46 ~ 54V |
54 ~ 60V | 59 ~ 66V | |
Protection type: Shut down o/p voltage, re-power on to recover |
||||||||||
|
||||||||||
Environment: |
Working Temp. |
-40 ~ +70°C (Refer to "Derating Curve") |
||||||||
Working Humidity |
20 ~ 95% RH non-condensing |
|||||||||
Storage Temp., Humidity |
-40 ~ +80°C, 10 ~ 95% RH |
|||||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
|||||||||
Vibration |
10 ~ 500Hz, 5G 12min. / 1 cycle 72 min. each along X, Y, Z axes |
|||||||||
Safety & EMC |
Safety Standards |
UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved; Design refer to EN60335-1 |
||||||||
Withstand Voltage |
I/P-O/P:3.75KVAC |
|||||||||
Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH |
|||||||||
EMC Emission |
Compliance to EN55015, EN61000-3-2 Class C (?60% load) ; EN61000-3-3 |
|||||||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge 2KV), criteria A |
|||||||||
Others: |
MTBF |
368Khrs min. MIL-HDBK-217F (25°C) |
||||||||
Dimension |
150*53*35mm (L*W*H) |
|||||||||
Packing |
0.49Kg; 30pcs / 15.7Kg / 1.0CUFT |
Electrical Specifications | |
Dimensions | 5.9 x 2.1 x 1.4 in (L*W*H) |
Input Voltage | 90~305VAC |
Number of Outputs | 1 |
Output Voltage | 42V |
Wattage | 60 |
General | |
Industry Aliases | new |
NPF-60-42