Mean Well Authorized Distributor since 1997
Model No. OWA-120U Series
Max Output Wattage (W) - 120 Watts
Output Voltage (VDC) – 12, 15, 20, 24, 30, 36, 42, 48, 54 Volts
Model No. |
OWA-120U-20 |
OWA-120U-30 |
OWA-120U-36 |
OWA-120U-42 |
OWA-120U-48 |
OWA-120U-54 |
|||||
Output: |
DC Voltage |
12V |
15V |
20V |
24V |
30V |
36V |
42V |
48V |
54V |
|
Constant Current Region |
7.2 ~ 12V |
9 ~ 15V |
12 ~ 20V |
14.4 ~ 24V |
18 ~ 30V |
21.6 ~ 36V |
25.2 ~ 42V |
28.8 ~ 48V |
32.4 ~ 54V |
||
Rated Current |
10A |
8A |
6A |
5A |
4A |
3.4A |
2.9A |
2.5A |
2.3A |
||
Rated Power |
120W |
120W |
120W |
120W |
120W |
122.4W |
121.8W |
120W |
124.2W |
||
Ripple & Noise (max.) Note 2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
250mVp-p |
250mVp-p |
350mVp-p |
||
Voltage Tolerance Note 3 |
±4.0% |
±4.0% |
±4.0% |
±4.0% |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
||
Line Regulation Note 4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||
Load Regulation Note 5 |
±2.0% |
±1.5% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||
Setup, Rise Time |
500ms, 80ms at 95% load 230VAC/115VAC |
||||||||||
Hold Up Time (typ.) |
16ms at full load 230VAC/115VAC |
||||||||||
Input: |
Voltage Range |
90~264VAC 127 ~ 370VDC |
|||||||||
Frequency Range |
47~63Hz |
||||||||||
Power Factor (typ.) |
PF>0.97/115VAC, PF>0.96/230VAC at full load |
||||||||||
Total Harmonic Distortion |
THD< 20% when output loading?60% at 115VAC/230VAC |
||||||||||
Efficiency (Typ.) |
115VAC |
87% |
88% |
89% |
89.5% |
89% |
89% |
89.5% |
89.5% |
89.5% |
|
230VAC |
87.5% |
89% |
90% |
90.5% |
90% |
90% |
90.5% |
90.5% |
90.5% |
||
AC Current (Typ.) |
1.3A/115VAC 0.65A/230VAC |
||||||||||
Inrush Current (Typ.) |
COLD START 30A (twidth=520us measured at 50% Ipeak) at 115VAC COLD START 60A (twidth=550us measured at 50% Ipeak) at 230VAC |
||||||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER |
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
||||||||||
Leakage Current |
<0.125mA / 120VAC <0.25mA / 240VAC |
||||||||||
Protection: |
Over Current |
95 ~ 108% |
|||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||||||||
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed |
||||||||||
Over Voltage |
15 ~ 17V |
17.5 ~ 21V |
23 ~ 27V |
28 ~ 34V |
34 ~ 40V |
41 ~ 46V |
46 ~ 54V |
54 ~ 60V |
59 ~ 66V |
||
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||||||
Environment: |
Working Temp. |
-40 ~ +70°C (Refer to "Derating Curve") |
|||||||||
Working Humidity |
20 ~ 95% RH non-condensing |
||||||||||
Storage Temp., Humidity |
-40 ~ +80°C, 10 ~ 95% RH |
||||||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
||||||||||
Vibration |
10 ~ 500Hz, 5G 12min. / 1cycle 72 min. each along X, Y, Z axes |
||||||||||
Safety & EMC |
Safety Standards |
UI8750 listed, CSA C22.2 No. 250.13-12 (except for 42V, 48V, 54V); IP67 (for power body) approved |
|||||||||
Withstand Voltage |
I/P-O/P:3.75VDC |
||||||||||
Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH |
||||||||||
EMC Emission |
Compliance to FCC Part15 |
||||||||||
MTBF |
294.3Khrs min. MIL-HDBK-217F(25?) |
||||||||||
Dimension |
7.5 x 2.5 x 1.5 in (L*W*H) |
||||||||||
Packing |
1 lbs; 12pcs / 14.8Kg / 0.89CUFT |
Electrical Specifications | |
Dimensions | 7.5 x 2.5 x 1.5 in (L*W*H) |
Number of Outputs | 1 |
Output Voltage | 24V |
PDF Specs | View Spec Sheet |
Wattage | 120 |
General | |
Industry Aliases | new |
OWA-120U-24
- Brand: Mean Well
- Product Code: OWA-120U-24
- Availability: Call for Availability
-
$49.10
- Ex Tax: $49.10