Model No. - ELG-200-C Series
Max Output Wattage (W) - 200 Watts
Rated Current - 700mA, 1050mA, 1400mA, 1700mA, 2100mA
Model No. |
ELG-200-C700 |
ELG-200-C1050 |
ELG-200-C1400 |
ELG-200-C1750 |
ELG-200-C2100 | |
Output |
Rated Current |
700mA |
1050mA |
1400mA |
1750mA |
2100mA |
Rated Power |
200VAC~305VAC |
|||||
200.2W |
199.5W |
198.8W |
199.5W |
201.6W | ||
100VAC~180VAC |
||||||
150.5W |
150.15W |
149.8W |
150.5W |
151.2W | ||
Constant Current Region |
142 ~ 286V |
95 ~190V |
71 ~ 142V |
57 ~ 114V |
48 ~ 96V | |
Open Circuit Voltage |
300V |
200V |
160V |
120V |
105V | |
Current ADJ. Range |
Adjustable for A-Type only (via built-in potentiometer) |
|||||
350 ~ 700mA |
525 ~ 1050mA |
700 ~ 1400mA |
875 ~ 1750mA |
1050 ~ 2100mA | ||
Current Ripple |
5.0% max. @rated current |
|||||
Current Tolerance |
±5.0% |
|||||
Set Up Time |
800ms/115VAC 500ms/230VAC |
|||||
Input: |
Voltage Range |
100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) |
||||
Frequency Range |
47~63Hz |
|||||
Power Factor (Typ.) |
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
|||||
Total Harmonic Distortion |
THD< 20%(@load≧50%/115VC,230VAC; @load≧75%/277VAC) |
|||||
Efficiency (Typ.) |
93% |
93% |
92% |
92% |
92% | |
AC Current (Typ.) |
1.8A / 115VAC 1.0A / 230VAC 1.0A/277VAC |
|||||
Inrush Current (Typ.) |
COLD START 65A(twidth=680μs measured at 50% Ipeak)/230VAC; Per NEMA 410 |
|||||
MAX. No. of PSUs on 16A |
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC |
|||||
Leakage Current |
<0.75mA / 277VAC |
|||||
No Load/Standby Power Consumption |
No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / DA-Type |
|||||
Protection: |
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed | ||||
Over Voltage |
315 ~ 370V | 205 ~ 250V |
160 ~ 180V |
125 ~ 150V |
105 ~ 130V | |
Shut down o/p voltage, re-power on to recover |
||||||
Over Temperature |
Shut down o/p voltage, re-power on to recover |
|||||
Environment: |
Working Temp. |
Tcase=-40 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) |
||||
Max. Case Temp |
Tcase=+85℃ |
|||||
Working Humidity |
20 ~ 95% RH non-condensing |
|||||
Storage Temp., Humidity |
-40 ~ +80°C, 10 ~ 95% RH |
|||||
Temp. Coefficient |
±0.03%/°C (0 ~ 60°C) |
|||||
Vibration |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
|||||
Safety & EMC |
Safety Standards |
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1, GB19510.14; IP65 or IP67 approved |
||||
Dali Standards |
Compliance to IEC62386-101, 102, 207 for DA-Type only |
|||||
Withstand Voltage |
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC |
|||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||
EMC Emission |
Compliance to EN55015,EN61000-3-2 Class C (@load≧50%) ; EN61000-3-3; GB17743, GB17625.1 |
|||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) |
|||||
Others: |
MTBF |
958.9K hrs min. Telcordia SR-332 (Bellcore) 235Khrs min. MIL-HDBK-217F (25℃) |
||||
Dimension |
244*71*37.5 mm (L*W*H) | |||||
Packing |
1.22Kg; 12pcs /15.2kg / 0.72CUFT |
Electrical Specifications | |
Dimensions | 244*71*37.5 mm (L*W*H) |
Input Voltage | NA |
Model Type | C-Type |
Number of Outputs | 1 |
Output Voltage | NA |
PDF Specs | View Spec Sheet |
Wattage | 108 |
General | |
Dimmable | Dimming |
Industry Aliases | new |
ELG-200-C1400 Mean Well LED Power Supply
- Brand: Mean Well
- Product Code: ELG-200-C1400
- Availability: Call for Availability
-
$47.70