Model No. HDP-240
Max Output Wattage (W) 227.7W(typ.) \ 241W(max.) Watts
Output Voltage (VDC) - V1 - +3.8V/ V2 - +2.8V Volts
Model No. | HDP-240 | |||||||||
Output | Output Number | V1 | V2 | |||||||
DC Voltage | +3.8V | +2.8V | ||||||||
Rated Current | 41.5A | 25A | ||||||||
Current Range (max.) | 0~50A | 0~27.5A | ||||||||
Rated Power | 227.7W (typ.) / 241W (max.) | |||||||||
Output Power (max.) |
241W continue. V1 total power output shall not exceed 200W (max. 50A) ; V2 total power output shall not exceed 82.5W (max. 27.5A) (The V1 & V2 combine total power output shall not exceed 241W) |
|||||||||
Ripple & Noise (max.) | 100mVp-p | 100mVp-p | ||||||||
Voltage Adj. Range | 3.6 ~ 4V | 2.5 ~ 3V | ||||||||
Voltage Tolerance | ±2.0% | ±2.0% | ||||||||
Line Regulation | ±0.5% | ±0.5% | ||||||||
Load Regulation | ±2.0% | ±2.0% | ||||||||
Setup, Rise Time | 1000ms, 50ms / 230VAC ---- 2500ms, 50ms / 115VAC at full load | |||||||||
Hold up Time | 16ms/230VAC - - -16ms/115VAC at full load | |||||||||
Input: | Voltage Range | 90 ~ 234VAC 127 ~ 370VDC | ||||||||
Frequency Range |
47~63Hz | |||||||||
Power Factor (Typ.) | PF>0.94/230VAC, PF>0.98/115VAC at full load | |||||||||
Efficiency (Typ.) | 84% | 84% | ||||||||
AC Current (Typ.) | 3.3A / 115VAC------1.3A / 230VAC | |||||||||
Inrush Current (Typ.) | 30A / 115VAC ------- 45A / 230VAC | |||||||||
Leakage Current | <0.7mA / 240VAC | |||||||||
Protection: | Overload | V1+V2: 105 ~ 150% max. output power ; or V2: 125 ~170% rated current | ||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
Over Voltage | V1: 4.37~5.13V | V2: 3.22~3.78V | ||||||||
Protection type: Shut down o/p voltage, re-power on to recovery | ||||||||||
Over Temperature | 80°C±5°C (CN2) detect on heatsink of power transistor | |||||||||
Protection type : shut down o/p voltage, re-power on to recovery | ||||||||||
Environment: | Working Temp. | -30 ~ +70°C (Refer to "Derating Curve") | ||||||||
Working Humidity | 20 ~ 90% RH non-condensing X | |||||||||
Storage Temp., Humidity | -40 ~ +85°C, 10 ~ 95% RH | |||||||||
Temp. Coefficient | ±0.03%/°C (0 ~ 50°C) | |||||||||
Vibration | 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes | |||||||||
Safety & EMC | Safety Standards | UL60950-1, TUV EN60950-1 approved | ||||||||
Withstand Voltage | I/P - O/P : 3KVAC -----I/P-FG:2KVAC ----O/P-FG: 0.5KVAC | |||||||||
Isolation Resistance | I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25°C / 70% RH | |||||||||
EMC Emission | Compliance to EN55022 (CISPR22) class B, EN61000-3-2,-3 | |||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, EN61000-6-2, heavy industry level, criteria A | |||||||||
Others: | MTBF | 111.3Khrs min. MIL-HDBK-217F (X°C) | ||||||||
Dimension | 215 x 115 x 36mm (LxWxH) | |||||||||
Packing | 1Kg; 15pcs / 16Kg/0.7CUFT |
Electrical Specifications | |
Input Voltage | 90 ~ 264 VAC Universal |
Number of Outputs | 2 |
Output Voltage | 3.8 |
PDF Specs | View Spec Sheet |
Wattage | 104 |
General | |
Industry Aliases | new |
HDP-240 Mean Well Power Supply
- Brand: Mean Well
- Product Code: HDP-240
- Availability: Call for Availability
-
$79.60
- Ex Tax: $79.60