Model No. - ELG-100-C Series
Max Output Wattage (W) - 100 Watts
Rated Current - 350mA, 500mA, 700mA, 1050mA, 1400mA
Model No. |
ELG-100-C350 |
ELG-100-C500 |
ELG-100-C700 |
ELG-100-C1050 |
ELG-100-C1400 |
|
Output |
Rated Current |
350mA |
500mA |
700mA |
1050mA |
1400mA |
Rated Power |
200VAC~305VAC |
|||||
100.1W |
100W |
100.1W |
99.75W |
100.8W |
||
100VAC~180VAC |
||||||
70W |
70W |
70W |
70.35W |
70W |
||
Constant Current Region |
143 ~ 286V |
100 ~ 200V |
71 ~ 143V |
48 ~ 95V |
35 ~ 72V |
|
Open Circuit Voltage |
297V |
210V |
149V |
105V |
75V |
|
Current ADJ. Range |
Adjustable for A-Type only (via built-in potentiometer) |
|||||
175 ~ 350mA |
250 ~ 500mA |
350 ~ 700mA |
525 ~ 1050mA |
700 ~ 1400mA |
||
Current Ripple |
5.0% max. @rated current |
|||||
Current Tolerance |
±5.0% |
|||||
Set Up Time |
1000ms/115VAC 500ms/230VAC |
|||||
Input: |
Voltage Range |
100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) |
||||
Frequency Range |
47~63Hz |
|||||
Power Factor (Typ.) |
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
|||||
Total Harmonic Distortion |
THD< 20%(@load≧50%/115VC,230VAC; @load≧75%/277VAC) |
|||||
Efficiency (Typ.) |
92% |
91% |
90% |
90% |
90% |
|
AC Current (Typ.) |
1.1A/115VAC 0.6A/230VAC 0.5A/277VAC |
|||||
Inrush Current (Typ.) |
COLD START 50A(twidth=760μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
|||||
MAX. No. of PSUs on 16A |
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
|||||
Leakage Current |
<0.75mA / 277VAC |
|||||
No Load/Standby Power Consumption |
No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / DA-Type |
|||||
Protection: |
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed | ||||
Over Voltage |
305 ~ 333V |
222 ~ 242V |
154 ~ 174V |
110 ~ 130V |
79 ~ 95V |
|
Shut down o/p voltage, re-power on to recover |
||||||
Over Temperature |
Shut down o/p voltage, re-power on to recover |
|||||
Environment: |
Working Temp. |
Tcase=-40 ~ +90℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) |
||||
Max. Case Temp |
Tcase=+90℃ |
|||||
Working Humidity |
20 ~ 95% RH non-condensing |
|||||
Storage Temp., Humidity |
-40 ~ +80°C, 10 ~ 95% RH |
|||||
Temp. Coefficient |
±0.03%/°C (0 ~ 60°C) |
|||||
Vibration |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
|||||
Safety & EMC |
Safety Standards |
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1,GB19510.14; IP65 or IP67 approved |
||||
Dali Standards |
Compliance to IEC62386-101, 102, 207 for DA-Type only |
|||||
Withstand Voltage |
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC |
|||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||
EMC Emission |
Compliance to EN55015,EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3; GB17743, GB17625.1 |
|||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) |
|||||
Others: |
MTBF |
1087.5K hrs min. Telcordia SR-332 (Bellcore) 300.6Khrs min. MIL-HDBK-217F (25℃) |
||||
Dimension |
199*63*35.5 mm (L*W*H) |
|||||
Packing |
0.85kg; 16pcs/14.2kg/0.72CUFT |
Electrical Specifications | |
Dimensions | 199*63*35.5 mm (L*W*H) |
Input Voltage | NA |
Model Type | C-Type |
Number of Outputs | 1 |
Output Voltage | NA |
PDF Specs | View Spec Sheet |
Wattage | 100 |
General | |
Dimmable | Dimming |
Industry Aliases | new |