Model No. - HLG-240H-12D
Max Output Wattage (W) - 240 Watts
Output Voltage (VDC) - 12 Volts
Please read!!
Blank : IP67 rated. Cable for I/O connection.
A - Type : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B - Type : IP67 rated. Constant current level adjustable through output cable with 1 ~ 10Vdc or 10V PWM signal or resistance.
C - Type : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal potentiometer
D - Type : (option) : IP67 rated. Timer dimming function, contact Peak to Peak for details.
Model No. | HLG-240H-12 | HLG-240H-12A | HLG-240H-12B | HLG-240H-12C | HLG-240H-12D | |
Output: | DC Voltage | 12V | ||||
Constant Current Region | 6~12V | |||||
Rated Current | 16A | |||||
Rated Power | 192W | |||||
Ripple & Noise (max.) | 150mVp-p | |||||
Voltage ADJ. Range | 11.2 ~ 12.8V | |||||
Current Adj. Range | Can be adjusted by internal potentiometer A type and d C type only |
|||||
8 ~ 16A |
||||||
Voltage Tolerance | ±2.5% | |||||
Line Regulation | ±0.5% | |||||
Load Regulation | ±2.0% | |||||
Setup, Rise Time | 2500ms, 80ms at full load 230VAC / 115VAC |
|||||
Hold up Time | 15ms at full load 230VAC/115VAC | |||||
Input: | Voltage Range | 90~305VAC 127~431VDC | ||||
Frequency Range |
47~63Hz | |||||
Power Factor (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve) | |||||
Efficiency (Typ.) (230Vac) | 90% | |||||
AC Current (Typ.) |
4A / 115VAC 2A / 230VAC 1.2A / 277VAC |
|||||
Inrush Current (Typ.) | COLD START 75A (twidth=570µS measured at 50% lpeak) at 230VAC | |||||
Leakage Current | <0.75mA / 277VAC | |||||
Protection: | Over Current | 95 ~ 108% | ||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||
Short Circuit Protection | Hiccup mode, recovers automatically after fault condition is removed |
|||||
Over Voltage | 13.5 ~ 18V | |||||
Protection type: Shut down and latch off o/p voltage, re-power on to recover |
||||||
Over Temperature | 105°C±5°C (TSW1) | |||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
||||||
Environment: | Working Temp. | -40 ~ +70°C (Refer to "Derating Curve") | ||||
Working Humidity | 20 ~ 95% RH non-condensing | |||||
Storage Temp., Humidity | -40 ~ +80°C, 10 ~ 95% RH | |||||
Temp. Coefficient | ±0.03%/°C (0 ~ 50°C) | |||||
Vibration | 10 ~ 500Hz, 5G 12min. / 1cycle, period for 72min. each along X, Y, Z axes | |||||
Safety & EMC | Safety Standards | UL1012, CAN / CSA- C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent, (except for HLG-240H C Type), UL60950-1, UL8750, TUVEN60950-1 IP65 or IP67 J61347-1 , J61347-2-13 approved |
||||
Withstand Voltage | I/P - O/P : 3.75KVAC-----I/P-FG : 2KVAC---- O/P-FG : 0.5KVAC | |||||
Isolation Resistance | I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25°C / 70% RH | |||||
EMC Emission | Compliance to EN550515, EN55022 (CISR22) Class B EN61000-3-2 Class C (>50%load) ; EN61000-3-3 |
|||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 4KV), criteria A | |||||
Others: | MTBF | 207.9K hrs min. MIL-HDBK-217F (25°C) | ||||
Dimension | 244.2 x 68 x 38.8mm (LxWxH)(HLG-240H- Bank/AB) 251 x 68 x 38.8mm (LxWxH)(HLG-240H-C) |
|||||
Packing | 1.3Kg; 12pcs / 16.6Kg / 0.84CUFT (HLG-240 - Blank/AB) 1.23Kg; 12pcs/15.8Jg/1.16CUFT (HLG-240C) |
(HLG-0
Electrical Specifications | |
Dimensions | 244 x 68 x 38.8mm |
Input Voltage | 90~305VAC |
Number of Outputs | 1 |
Output Rated Current | 16A |
Output Voltage | 12V |
PDF Specs | View Spec Sheet |
Wattage | 104 |
General | |
Dimmable | D (Option) : IP67 rated - Timer Dimming Function |
Industry Aliases | new |