Model No. - RCP-1600 Series
Max Output Wattage (W) - 1600 Watts
Output Voltage (VDC) – 12, 24, 48 Volts
Model No. |
RCP-1600-12 |
RCP-1600-24 |
RCP-1600-48 |
|||||||
Output: |
DC Voltage |
12V |
24V |
48V |
||||||
Rated Current |
125A |
67A |
33.5A |
|||||||
Current Range |
0 ~ 125A |
0 ~ 67A |
0 ~ 33.5A |
|||||||
Rated Power |
1500W |
1608W |
1608W |
|||||||
Ripple & Noise (max.) Note 2 |
150mVp-p |
200mVp-p |
300mVp-p |
|||||||
Voltage ADJ. Range |
11.5 ~ 15V |
23.5 ~ 30V |
47.5 ~ 58.8V |
|||||||
Voltage Tolerance Note 3 |
±1.0% |
±1.0% |
±1.0% |
|||||||
Line Regulation Note 4 |
±0.5% |
±0.5% |
±0.5% |
|||||||
Load Regulation Note 5 |
±0.5% |
±0.5% |
±0.5% |
|||||||
Setup, Rise Time |
1500ms, 60ms/230VAC at full load |
|||||||||
Hold up Time |
16ms / 230VAC @ 75% load 10ms / 230VAC at full load |
|||||||||
Input: |
Voltage Range |
90 ~ 264VAC 127 ~ 370VDC |
||||||||
Frequency Range |
47~63Hz |
|||||||||
Power Factor (typ.) |
0.97/230VAC at full load |
|||||||||
Efficiency (Typ.) |
88.5% |
91% |
93% |
|||||||
AC Current (Typ.) |
14A/115VAC 8A/230VAC |
15A/115VAC 8.5A/230VAC |
||||||||
Inrush Current (Typ.) |
COLD START 35A/230VAC |
|||||||||
Leakage Current |
<1.5mA / 230VAC |
|||||||||
Protection: |
Over Load |
105 ~ 115% rated output power |
||||||||
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover |
||||||||||
Over Voltage |
15.75 ~ 18.75V |
31.5 ~ 37.5V | 63 ~ 75V | |||||||
Protection type: Shut down o/p voltage, re-power on to recover |
||||||||||
Over Temperature: |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
|||||||||
Function: |
OUTPUT VOLTAGE PROGRAMMABLE(PV) |
Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). |
||||||||
CONSTANT CURRENT LEVEL PROGRAMMABLE(PC) |
Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual. |
|||||||||
AUXILIARY POWER |
5V @ 0.3A, 12V @ 0.8A |
|||||||||
REMOTE ON-OFF CONTROL |
By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual in following pages. |
|||||||||
REMOTE SENSE |
Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages. |
|||||||||
ALARM SIGNAL |
Isolated signal output for T-alarm, AC-OK and DC-OK |
|||||||||
Environment: |
Working Temp. |
-30 ~ +70°C (Refer to "Derating Curve") |
||||||||
Working Humidity |
20 ~ 90% RH non-condensing |
|||||||||
Storage Temp., Humidity |
-40 ~ +85°C, 10 ~ 95% RH |
|||||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
|||||||||
Vibration |
10 ~ 500Hz, 5G 10min. / 1cycle 60 min. each along X, Y, Z axes |
|||||||||
Safety & EMC |
Safety Standards |
UL60950-1, TUV EN60950-1 approved |
||||||||
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC (0.5KVAC for 12V) |
|||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH |
|||||||||
EMC Emission |
Parameter |
Standard |
Test Level / Note |
|||||||
Conducted |
EN55022 (CISPR22) / EN55011 (CISPR11) |
Class B |
||||||||
Radiated |
EN55022 (CISPR22) / EN55011 (CISPR11) |
Class A |
||||||||
Harmonic Current |
EN61000-3-2 |
----------- |
||||||||
Voltage Flicker |
EN61000-3-3 |
------------ |
||||||||
EMC Immunity |
EN55024 , EN61204-3, EN61000-6-2 |
|||||||||
Parameter |
Standard |
Test Level / Note |
||||||||
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 2, 4KV contact |
||||||||
Radiated |
EN61000-4-3 |
Level 3 |
||||||||
EFT / Burst |
EN61000-4-4 |
Level 3 |
||||||||
Surge |
EN61000-4-5 |
Level 4, 1KV/Line-Line 2KV/Line-Earth |
||||||||
Conducted |
EN61000-4-6 |
Level 3 |
||||||||
Magnetic Field |
EN61000-4-8 |
Level 4 |
||||||||
Voltage Dips and Interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods, |
||||||||
Others: |
MTBF |
162.2K hrs min. Telcordia SR-332 (Bellcore) ; 39.3K hrs min. MIL-HDBK-217F (25?) |
||||||||
Dimension |
11.8 x 3.35 x 1.6 in (L*W*H) |
|||||||||
Packing |
4lbs; 6pcs / 12.2Kg / 1.16CUFT |
Electrical Specifications | |
Dimensions | 11.8 x 3.35 x 1.6 in (L*W*H) |
Number of Outputs | 1 |
Output Voltage | 12V |
PDF Specs | View Spec Sheet |
General | |
Industry Aliases | new |
RCP-1600-12
- Brand: Mean Well
- Product Code: RCP-1600-12
- Availability: Call for Availability
-
$491.30
- Ex Tax: $491.30