web statistics
  • OWA-120E-42


Mean Well Authorized Distributor since 1997

Model No. OWA-120E Series

Max Output Wattage (W) - 120 Watts

Output Voltage (VDC) – 12, 15, 20, 24, 30, 36, 42, 48, 54 Volts

Model No.

OWA-120E-12

OWA-120E-15

OWA-120E-20

OWA-120E-24

OWA-120E-30

OWA-120E-36

OWA-120E-42

OWA-120E-48

OWA-120E-54

Output: 

DC Voltage

12V

15V

20V

24V

30V

36V

42V

48V

54V

Rated Current

10A

8A

6A

5A

4A

3.4A

2.9A

2.5A

2.3A

Rated Power

115.2W

120W

120W

120W

120W

122.4W

121.8W

120W

124.2W

Ripple & Noise (max.) Note 2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

250mVp-p

250mVp-p

350mVp-p

Voltage Tolerance Note 3

±4.0%

±4.0%

±4.0%

±4.0%

±3.0%

±2.0%

±1.0%

±1.0%

±1.0%

Line Regulation Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation Note 5

±2.0%

±1.5%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Setup, Rise Time

500ms, 80ms at 95% load        230VAC

Hold Up Time (typ.)

16ms at full load         230VAC

Input:

Voltage Range

90~264VAC          254 ~ 370VDC

Frequency Range

47~63Hz

Power Factor (typ.)

PF>0.96/230VAC at full load

Efficiency (Typ.)

 87.5%

89% 90% 90.5% 90% 90% 90.5% 90.5% 90.5%

AC Current (Typ.)

0.65A/230VAC

Inrush Current (Typ.)

COLD START 60A (twidth=550us measured at 50% Ipeak) at 230VAC

Leakage Current

<0.25mA / 240VAC

Protection:

Over Current

105 ~ 115%

Protection type : Hiccup mode, recovers automatically after fault condition is removed

Short Circuit

Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

15 ~ 17V

17.5 ~ 21V

23 ~ 27V

28 ~ 34V

34 ~ 40V

41 ~ 46V

46 ~ 54V

54 ~ 60V

59 ~ 66V

Protection type : Shut down o/p voltage, re-power on to recover

Environment:

Working Temp.

-40 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 95% RH non-condensing

Storage Temp., Humidity

-40 ~ +80°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 40°C)

Vibration

10 ~ 500Hz, 5G 12min. / 1cycle 72 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

DEKRA EN61558-1,-2-16; DEKRA EN60335-1 (except for OWA-120E-48,54); IP67 (for power body) approved

Withstand Voltage

I/P-O/P:3.75VDC

Isolation Resistance

I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH

EMC Emission

Compliance to EN55022 (CISPR22) Class B, EN55014-1, EN61000-3-2,-3

EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55014-2, EN55024, light industry level (surge L- N : 2KV), criteria A
Others

MTBF

294.3Khrs min. MIL-HDBK-217F(25?)

Dimension

7.5 x 2.5 x 1.5 in (L*W*H)

Packing

1 lbs; 12pcs / 14.8Kg / 0.89CUFT

 

 

 

Electrical Specifications
Dimensions 7.5 x 2.5 x 1.5 in (L*W*H)
Number of Outputs 1
Output Voltage 42V
PDF Specs View Spec Sheet
Wattage 120
General
Industry Aliases new

OWA-120E-42

  • Brand: Mean Well
  • Product Code: OWA-120E-42
  • Availability: Call for Availability
  • $49.10

  • Ex Tax: $49.10

©2024 Peak to Peak Power, Inc. All Rights Reserved. Marketing by Digital Lightbridge.