Mean Well Authorized Distributor since 1997
Model No. OWA-90E Series
Max Output Wattage (W) - 90 Watts
Output Voltage (VDC) – 12, 15, 20, 24, 30, 36, 42, 48, 54 Volts
Model No. |
OWA-90E-20 |
OWA-90E-30 |
OWA-90E-36 | OWA-90E-42 | OWA-90E-48 | OWA-90E-54 | ||||
Output: |
DC Voltage |
12V |
15V |
20V |
24V |
30V |
36V | 42V | 48V | 54V |
Rated Current |
7.5A |
6A |
4.5A |
3.75A |
3A |
2.5A | 2.15A | 1.88A | 1.67A | |
Rated Power |
90W |
90W |
90W |
90W |
90W |
90W | 90.3W | 90.24W | 90.18W | |
Ripple & Noise (max.) Note 2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | |
Voltage Tolerance Note 3 |
±4.0% |
±4.0% |
±4.0% |
±3.0% |
±3.0% |
±2.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation Note 4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation Note 5 |
±1.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup, Rise Time |
500ms, 80ms at 95% load 115VAC/230VAC |
|||||||||
Hold Up Time (typ.) |
16ms at full load 115VAC/230VAC |
|||||||||
Input: |
Voltage Range |
90~264VAC 127 ~ 370VDC |
||||||||
Frequency Range |
47~63Hz |
|||||||||
Power Factor (typ.) | PF>0.98/115VAC, PF>0.96/230VAC at full load | |||||||||
Efficiency (Typ.) |
89% |
90% |
90% |
90% |
90% |
91% | 91% | 91% | 91% | |
AC Current (Typ.) |
0.95A/115VAC 0.5A/230VAC |
|||||||||
Inrush Current (Typ.) |
COLD START 65A(twidth=750us measured at 50% Ipeak) at 230VAC |
|||||||||
Leakage Current |
<0.25mA / 240VAC |
|||||||||
Protection: |
OverLoad |
105 ~ 115% |
||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||||||||||
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed | |||||||||
Over Voltage |
15 ~ 17V |
17.5 ~ 21V | 23 ~ 27V | 28 ~ 34V | 34 ~ 40V | 41 ~ 46V | 46 ~ 54V | 54 ~ 60V | 59 ~ 66V | |
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||||
Environment: |
Over Temperature |
Shut down o/p voltage, re-power on to recover |
||||||||
Working Temp. |
-40 ~ +70°C (Refer to "Derating Curve") |
|||||||||
Working Humidity |
20 ~ 95% RH non-condensing |
|||||||||
Storage Temp., Humidity |
-40 ~ +80°C, 10 ~ 95% RH |
|||||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
|||||||||
Vibration |
10 ~ 500Hz, 5G 12min. / 1cycle 72 min. each along X, Y, Z axes |
|||||||||
Safety & EMC
|
Safety Standards |
EN61558-1,-2-16 listed; EN60335-1 listed(except for OWA-90E-42,48,54); IP67 approved | ||||||||
Withstand Voltage |
I/P-O/P:3.75KVDC | |||||||||
Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH | |||||||||
EMC Emission |
Compliance to EN55022 (CISPR22) Class B, EN55014-1, EN61000-3-2,-3 | |||||||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L-N: 2KV), criteria A |
|||||||||
Others: | MTBF | 292.8Khrs min. MIL-HDBK-217F(25?) | ||||||||
Dimension |
6.7 x 2.5 x 1.5 in (L*W*H) |
|||||||||
Packing |
1.8 lbs; 16pcs / 15.7Kg / 1.01CUFT |
Electrical Specifications | |
Dimensions | 6.7 x 2.5 x 1.5 in (L*W*H) |
Number of Outputs | 1 |
Output Voltage | 15V |
PDF Specs | View Spec Sheet |
Wattage | 90 |
General | |
Industry Aliases | new |