web statistics
  • OWA-120U-54


Mean Well Authorized Distributor since 1997

Model No. OWA-120U Series

Max Output Wattage (W) - 120 Watts

Output Voltage (VDC) – 12, 15, 20, 24, 30, 36, 42, 48, 54 Volts

Model No.

OWA-120U-12

OWA-120U-15

OWA-120U-20

OWA-120U-24

OWA-120U-30

OWA-120U-36

OWA-120U-42

OWA-120U-48

OWA-120U-54

Output: 

DC Voltage

12V

15V

20V

24V

30V

36V

42V

48V

54V

Constant Current Region

7.2 ~ 12V

9 ~ 15V

12 ~ 20V

14.4 ~ 24V

18 ~ 30V

21.6 ~ 36V

25.2 ~ 42V

28.8 ~ 48V

32.4 ~ 54V

Rated Current

10A

8A

6A

5A

4A

3.4A

2.9A

2.5A

2.3A

Rated Power

120W

120W

120W

120W

120W

122.4W

121.8W

120W

124.2W

Ripple & Noise (max.) Note 2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

250mVp-p

250mVp-p

350mVp-p

Voltage Tolerance Note 3

±4.0%

±4.0%

±4.0%

±4.0%

±3.0%

±2.0%

±1.0%

±1.0%

±1.0%

Line Regulation Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation Note 5

±2.0%

±1.5%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Setup, Rise Time

500ms, 80ms at 95% load        230VAC/115VAC

Hold Up Time (typ.)

16ms at full load         230VAC/115VAC

Input:

Voltage Range

90~264VAC          127 ~ 370VDC

Frequency Range

47~63Hz

Power Factor (typ.)

PF>0.97/115VAC, PF>0.96/230VAC at full load

Total Harmonic Distortion

THD< 20% when output loading?60% at 115VAC/230VAC

Efficiency (Typ.)

 115VAC

87%

88%

89%

89.5%

89%

89%

89.5%

89.5%

89.5%

 230VAC

 87.5%

 89%

 90%

 90.5%

 90%

 90%

 90.5%

 90.5%

 90.5%

AC Current (Typ.)

1.3A/115VAC               0.65A/230VAC

Inrush Current (Typ.)

COLD START 30A (twidth=520us measured at 50% Ipeak) at 115VAC

COLD START 60A (twidth=550us measured at 50% Ipeak) at 230VAC

MAX. NO. of PSUs on 16A CIRCUIT BREAKER

4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC

Leakage Current

<0.125mA / 120VAC <0.25mA / 240VAC

Protection:

Over Current

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

Short Circuit

Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

15 ~ 17V

17.5 ~ 21V

23 ~ 27V

28 ~ 34V

34 ~ 40V

41 ~ 46V

46 ~ 54V

54 ~ 60V

59 ~ 66V

Protection type : Shut down o/p voltage, re-power on to recover

Environment:

Working Temp.

-40 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 95% RH non-condensing

Storage Temp., Humidity

-40 ~ +80°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 50°C)

Vibration

10 ~ 500Hz, 5G 12min. / 1cycle 72 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

UI8750 listed, CSA C22.2 No. 250.13-12 (except for 42V, 48V, 54V); IP67 (for power body) approved

Withstand Voltage

I/P-O/P:3.75VDC

Isolation Resistance

I/P-O/P:100M Ohms / 500VDC / 25?/ 70% RH

EMC Emission

Compliance to FCC Part15

MTBF

294.3Khrs min. MIL-HDBK-217F(25?)

Dimension

7.5 x 2.5 x 1.5 in (L*W*H)

Packing

1 lbs; 12pcs / 14.8Kg / 0.89CUFT

 

 

Electrical Specifications
Dimensions 7.5 x 2.5 x 1.5 in (L*W*H)
Number of Outputs 1
Output Voltage 54V
PDF Specs View Spec Sheet
Wattage 120
General
Industry Aliases new

OWA-120U-54

  • Brand: Mean Well
  • Product Code: OWA-120U-54
  • Availability: Call for Availability
  • $49.10

  • Ex Tax: $49.10