Model No. - RCP-1600 Series

Max Output Wattage (W) - 1600 Watts

Output Voltage (VDC) – 12, 24, 48 Volts

Model No.

RCP-1600-12

RCP-1600-24

RCP-1600-48



Output: 

DC Voltage

12V

24V

48V

Rated Current

125A

67A

33.5A

Current Range

0 ~ 125A

0 ~ 67A

0 ~ 33.5A

Rated Power

1500W

1608W

1608W

Ripple & Noise (max.) Note 2

150mVp-p

200mVp-p

300mVp-p

Voltage ADJ. Range

11.5 ~ 15V

23.5 ~ 30V

47.5 ~ 58.8V

Voltage Tolerance Note 3

±1.0%

±1.0%

±1.0%

Line Regulation Note 4

±0.5%

±0.5%

±0.5%

Load Regulation Note 5

±0.5%

±0.5%

±0.5%

Setup, Rise Time

1500ms, 60ms/230VAC at full load

Hold up Time

16ms / 230VAC @ 75% load 10ms / 230VAC at full load

Input:

Voltage Range

90 ~ 264VAC 127 ~ 370VDC

Frequency Range

47~63Hz

Power Factor (typ.)

0.97/230VAC at full load

Efficiency (Typ.)

88.5%

 91%

 93%

AC Current (Typ.)

14A/115VAC 8A/230VAC

 15A/115VAC 8.5A/230VAC

Inrush Current (Typ.)

COLD START 35A/230VAC

Leakage Current

<1.5mA / 230VAC

Protection:

Over Load

105 ~ 115% rated output power

Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover

Over Voltage

15.75 ~ 18.75V

31.5 ~ 37.5V 63 ~ 75V

Protection type: Shut down o/p voltage, re-power on to recover

Over Temperature:

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

Function:

OUTPUT VOLTAGE PROGRAMMABLE(PV)

Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V).
Please refer to the Function Manual.

CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)

Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.

AUXILIARY POWER

5V @ 0.3A, 12V @ 0.8A

REMOTE ON-OFF CONTROL

By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual in following pages.

REMOTE SENSE

Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages.

ALARM SIGNAL

Isolated signal output for T-alarm, AC-OK and DC-OK

Environment:

Working Temp.

-30 ~ +70°C (Refer to "Derating Curve")

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 50°C)

Vibration

10 ~ 500Hz, 5G 10min. / 1cycle 60 min. each along X, Y, Z axes

Safety & EMC

Safety Standards

UL60950-1, TUV EN60950-1 approved

Withstand Voltage

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC (0.5KVAC for 12V)

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH

EMC Emission

Parameter

Standard

Test Level / Note

Conducted

EN55022 (CISPR22) / EN55011 (CISPR11)

Class B

Radiated

EN55022 (CISPR22) / EN55011 (CISPR11)

Class A

Harmonic Current

EN61000-3-2

-----------

Voltage Flicker

EN61000-3-3

------------

EMC Immunity

EN55024 , EN61204-3, EN61000-6-2

Parameter

Standard

Test Level / Note

ESD

EN61000-4-2

Level 3, 8KV air ; Level 2, 4KV contact

Radiated

EN61000-4-3

Level 3

EFT / Burst

EN61000-4-4

Level 3

Surge

EN61000-4-5

Level 4, 1KV/Line-Line 2KV/Line-Earth

Conducted

EN61000-4-6

Level 3

Magnetic Field

EN61000-4-8

Level 4

Voltage Dips and Interruptions

EN61000-4-11

>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods

Others:

MTBF

162.2K hrs min. Telcordia SR-332 (Bellcore) ; 39.3K hrs min. MIL-HDBK-217F (25?)

Dimension

11.8 x 3.35 x 1.6 in (L*W*H)

Packing

4lbs; 6pcs / 12.2Kg / 1.16CUFT

 

 

 

Electrical Specifications
Dimensions 11.8 x 3.35 x 1.6 in (L*W*H)
Number of Outputs 1
Output Voltage 12V
PDF Specs View Spec Sheet